Fire Safety You Can Trust In Bothell WA
Since 2008, Northwest Fire Systems has been providing the ultimate in fire protection services to the people of Bothell, WA and the surrounding areas. When it comes to fire safety, they are second to none.
Read below to find out what your neighbors in Bothell, WA have to say about our service, then call us to ensure your home or business is protected!
Recent Jobs and Reviews in Bothell, WA
Our Local Reviews by City
- Auburn, WA (29)
- Bellevue, WA (75)
- Black Diamond, WA (1)
- Bothell, WA (23)
- Bremerton, WA (5)
- Burien, WA (11)
- Burlington, WA (1)
- Carnation, WA (1)
- Centralia, WA (7)
- Chehalis, WA (2)
- Covington, WA (9)
- Des Moines, WA (4)
- DuPont, WA (7)
- Duvall, WA (2)
- Edgewood, WA (7)
- Edmonds, WA (1)
- Enumclaw, WA (3)
- Everett, WA (35)
- Fall City, WA (2)
- Federal Way, WA (30)
- Ferndale, WA (7)
- Fife, WA (2)
- Gig Harbor, WA (2)
- Granite Falls, WA (3)
- Hoquiam, WA (3)
- Issaquah, WA (21)
- Kenmore, WA (8)
- Kennewick, WA (1)
- Kent, WA (51)
- Kirkland, WA (19)
- Lacey, WA (19)
- Lakewood, WA (4)
- Lynnwood, WA (28)
- Maple Valley, WA (1)
- Marysville, WA (1)
- Mill Creek, WA (3)
- Milton, WA (7)
- Monroe, WA (1)
- Mukilteo, WA (4)
- Normandy Park, WA (2)
- North Bend, WA (6)
- Olympia, WA (24)
- Parkland, WA (1)
- Port Orchard, WA (4)
- Port Townsend, WA (3)
- Poulsbo, WA (2)
- Puyallup, WA (24)
- Redmond, WA (48)
- Renton, WA (39)
- Sammamish, WA (3)
- SeaTac, WA (22)
- Seattle, WA (358)
- Shelton, WA (2)
- Shoreline, WA (5)
- Silverdale, WA (2)
- Steilacoom, WA (1)
- Sumner, WA (7)
- Tacoma, WA (87)
- Tukwila, WA (35)
- Tumwater, WA (1)
- University Place, WA (1)
- Woodinville, WA (3)
Job Locations and Reviews
Annual Low Point Drain
We are pleased to know your experience with us was a good one!
Located (1) bad Potter PAD-100-MIM address 28. This device is located inside the attic. Will need to replace to clear trouble.
Tested Building 5 alarms to verify which device in RM S181 was inop, found that all ceiling mounted devices functioned properly during this test. Building 4 had a no answer trouble, located wall mounted strobe PT 37 outside RM N151, upon remove and remounting device the no answer trouble cleared. If this issue returns will need to replace (1) 49VO-WWF
Devices in need of replacement are addressable part number: 4906-9230 the devices I was sent with were 4906-9130 non-addressable. Customer had (2) in stock used (1) for device in building 4. Building 5 devices was written up as RM S181 located on ceiling, there are more than one device in this room. Will need to gather more information from the inspectors before replacement is made. Customer would like us to also order the correct part so he can refill his stock. Nathan-2hrs
Zone 3 trouble upon arrival this zone is for the 3rd floor. The circuit is showing EOL and has power. Tried putting resistor across terminals to see if this issue would clear. Also tried to take zone 2 off and place it on zone 3. Concluded that the Zone card is bad on the panel causing the constant trouble. Will need to replace (1) ESL 1503.
Dry sprinklers assessment
Thank you for sharing your kind words with us. It means the world to us and to our entire team!
So glad we were able to help you with your fire protection services. We appreciate you business and the 5 star review!