Northwest Fire Systems provides complete fire protection services to commercial clients in Puyallup, WA and the surrounding areas since 2008. From installing fire alarm and sprinkler systems to completing scheduled testing and maintenance, we make sure your property is safe from fire.

We have the best people and customer service, and provide the best value for your money. Read our reviews to see why Northwest Fire Systems is THE fire protection leader in Puyallup, WA.

Local Reviews
for Puyallup, WA

Northwest Fire Systems Rated 5.0 out of 5 stars based on 5 customer reviews


Grate service,




Review of Northwest Fire Systems

Good customer relation ship.


Great attitude




Review of Northwest Fire Systems

great at letting us know what was done


Marlow J.




Review of Northwest Fire Systems

I believe the tech's name was Marlow. Marlow was in and out quick and clean it seemed like. He helped me call to put the system in test and take it out as I did not know how, because I am a new hire. He was also friendly with my co-workers. I hope to see Marlow again.


Great service




Review of Northwest Fire Systems


On time/well planed/all around coverage/efficient work and knowledge.




Review of Northwest Fire Systems

give a summery or explain the work you have done or service on site before you sign off for the day to who ever in-charge of your customer.


Marc P.

Marc P.

Deficiency Repairs Silent Knight 5207 FA-1 /: Fire alarm batteries are due for replacement. 2 x 12v 8ah batteries Watts 007DC Unreadable BFP-1 / Vault Near FDC: Unable to test domestic backflow during annual inspection. Backflow is located in vault - Vault needs to be pumped out and backflow tested. Dry SPK-1 / Laundry Room Bottom Floor: 4” Grinnell F3021 face plate gasket is leaking - Recommend replacement of face plate gasket. Dry SPK-1 / Laundry Room Bottom Floor: Grinnell F3021 Valve did not trip under 60 seconds - Will need an accelerator installed. Note: the drain is piped up, and there is no drain for the ITV upstairs to empty. Will need hose bib and 50' foot hose. Febco 806YD B589 BFP-4 / Riser Room: Backflow failed testing. #1 check valve failed - Recommend replacement of #1 check valve assembly. 4" Febco 806YD Serial #B589 Located in fire sprinkler riser room. Febco 805Y W1570 BFP-5 / Riser Room: Backflow failed testing. #1 & #2 check valves failed - Recommend replacement

Near S Hill Park Dr, Puyallup, WA 98373
Jesse S.

Jesse S.

Near 15th Ave SW, Puyallup, WA 98371
Colby F.

Colby F.

Near 111th St E, Puyallup, WA 98373
Marlon J.

Marlon J.

Near S Hill Park Dr, Puyallup, WA 98373
Jesse S.

Jesse S.

Near E Main Ave, Puyallup, WA 98372
Colby F.

Colby F.

Near 15th Ave SW, Puyallup, WA 98371
Jesse S.

Jesse S.

Near E Main Ave, Puyallup, WA 98372
Marlon J.

Marlon J.

Near 31st Ave SE, Puyallup, WA 98374
Brian R.

Brian R.

Replaced all batteries

Near 15th Ave SW, Puyallup, WA 98371
Brian R.

Brian R.

Annual FA inspection

Near 15th Ave SW, Puyallup, WA 98371
Allec B.

Allec B.

Near S Hill Park Dr, Puyallup, WA 98373
Doug D.

Doug D.

Near S Hill Park Dr, Puyallup, WA 98373
Thomas M.

Thomas M.

Annual Fire Alarm, Sprinkler, Backflow, and Fire Extinguisher Inspection

Near S Hill Park Dr, Puyallup, WA 98373
Grant  L.

Grant L.

Near 156th St E, Puyallup, WA 98374
Colby F.

Colby F.

Near 29th St NE, Puyallup, WA 98372
Brian R.

Brian R.

Annual fire alarm inspection not complete. Wenses Fernando requests to reschedule for horn and strobe testing as well as units that were not accessible today. Added pictures of units that were tested today Sprinkler inspection was completed today.

Near 15th Ave SW, Puyallup, WA 98371
Larry M.

Larry M.

Fire Alarm Diagnosis

Near 31st Ave SE, Puyallup, WA 98374
Jesse S.

Jesse S.

Near S Hill Park Dr, Puyallup, WA 98373
Larry M.

Larry M.

Near S Hill Park Dr, Puyallup, WA 98373
Marlon J.

Marlon J.

Near S Hill Park Dr, Puyallup, WA 98373
Marc P.

Marc P.

Annual Sprinkler, Standpipe, Fire Alarm, Backflow, and Fire Extinguisher Inspection

Near S Hill Park Dr, Puyallup, WA 98373
Brian R.

Brian R.

Tested and confirmed duct smoke operation and shutdown of air handler units. Dampers did not change state upon activation or deactivation of air handler units . Hvac company should be called to check damper operation

Near S Hill Park Dr, Puyallup, WA 98373
Marc P.

Marc P.

Deficiency Repairs Wilkins 375ADA X18278 BFP-3 Hot box on Eastside: Backflow failed testing. Relief failed needs replaced. Wilkins 375A 4” Serial #X18278 Backflow Repair