Northwest Provides Fire Protection Installation, Inspection, Maintenance & More

Northwest Fire Systems offers all the fire protection services you can possibly need in Seattle, WA so that you can work with one provider instead of several. Just a few of our services include fire alarm system installation and testing, fire sprinkler system installation and maintenance, and fire extinguisher recharge services.

Our company is family owned and operated and committed to providing you with fire protection services that perfectly fit your facility’s needs. Read our customer reviews to see why other businesses in the Seattle area rely on Northwest Fire Systems.

Local Reviews
for Seattle, WA

Rated 4.9 out of 5 stars based on 24 customer reviews


Jamie is Great





Thank you!!!!




We've had ongoing problems with our system and no one has been able to get to the bottom of it until the gentleman you sent out here last week. He was diligent about figuring it out. After he left my maintenance supervisor said, "that guy knows what he's doing!, he's good."


Great as always




Zeke is one of the best technicians you have. It is always a pleasure having Zeke doing our repairs. He is knowledgeable, thorough and courteous.


Excellent Knowledgeable Service





Good service, as usual





Dedicated, above and beyond




Jeff went above and beyond during his semi-annual check. He noticed something that wasn't quite right and fixed it. I appreciated that he didn't just note it and move one. He also was great in his helping to educate me on the system's workings.


Great Service!




Love using Northwest Fire! They are friendly, fast and knowledgeable.


thank you




thank you


Gret Service




Excellent Compny


Great Service




Thorough, quick, awesome job


Zeke  D.

Zeke D.

Quarterly Fire Alarm During normal business days/hours DEC 12- ROOF Confirmed with Terry/Tony/Ryder - Tony cell 206.495.8215Alarm Systems Inspection Simplex 4100ES FA-1 Fire Command Center: Quarterly Fire Alarm During normal business days/hours MARCH FLOORS A-E/ JUNE FLOORS 1-5 / SEPT FLOORS 6-11 / DEC 12- ROOF / Simplex 4100ES FA-2 1st floor Control Room: Quarterly Fire Alarm During normal business days/hours MARCH FLOORS A-E/ JUNE FLOORS 1-5 / SEPT FLOORS 6-11 / DEC 12- ROOF (labor hours and fees included in first FA service entry)

Near 9th Ave, Seattle, WA 98101
Allec B.

Allec B.

Near Rainier Ave S, Seattle, WA 98118
Jeff M.

Jeff M.

Near Seneca St, Seattle, WA 98101
Marc P.

Marc P.

MARLON YOU'RE THE LEAD ON THIS. ON SITE TIME IS 8AM 5 Year Certification - 28 PRV's; 2 Dry, 1 Wet and 25 section IPE's; 55+ Gauges @ $25/each. Confirmed with Gabe Ramirez

Near 2nd Ave, Seattle, WA 98101
Jeff M.

Jeff M.

Near University St, Seattle, WA 98101
Jamie Y.

Jamie Y.

Near S Norfolk St, Seattle, WA 98118
Jesse S.

Jesse S.

Near SW Dawson St, Seattle, WA 98136
Jamie Y.

Jamie Y.

Near 2nd Ave, Seattle, WA 98101
Jeff M.

Jeff M.

Near Pine St, Seattle, WA 98101
Jesse S.

Jesse S.

Confirmed with Tom Radio Monitoring Conversion - Call Brady with questions - AESB840 Alarm Center account number Radio is staged on service shelf per Brady

Near 5th Ave NE, Seattle, WA 98115
Zeke  D.

Zeke D.

Annual Fire Alarm - December - Central Tower Flrs 15-18, East Tower Flrs 15-19, North Tower Flrs 15-20 and West Wing Flrs 1-3; Quarterly Sprinkler Inspection Confirmed with Sean - Canned air/smoke at ADI KentAlarm Systems, Sprinkler, and Fire Protection Inspection Siemens XLS Firefinder FA-1 FACP Control Room: Annual Fire Alarm on 25% of towers completed quarterlyMarch- Central Tower Flrs 10-14, East Tower Flrs 10-14, North Tower Flrs 10-14 And West Wing No Inspection June- Central Tower Flrs 5-9, East Tower Flrs 5-9, North Tower Flrs 5-9 and West wing Flrs A & B September - Central Tower Flrs B-4, East Tower Flrs B-4, North Tower Flrs B5-4 and West Wing - Flrs H-C December - Central Tower Flrs 15-18, East Tower Flrs 15-19, North Tower Flrs 15-20 and West Wing Flrs 1-3Dry SPK-1 Level E central parking: Annual Sprinkler Inspection (6) Drys and (1) Pre Action - Due In June Quarterly Sprinkler Inspection (6) Drys and (1) Pre-Action 100% Tampers and flows - Due In March, September &

Near University St, Seattle, WA 98101
Zeke  D.

Zeke D.

Check in with Tony C 206.495.8215

Near 9th Ave, Seattle, WA 98101
Zeke  D.

Zeke D.

Quarterly Fire Alarm Inspection - December floors 6-11 Confirmed with JenniferAlarm Systems Inspection Gamewell E3 Series FA-1 NEW: Quarterly Fire Alarm Inspection - Must be done after hoursAugust floors 1-5 December floors 6-11 March floors 12-16Annual Due in June Deficiency for Gamewell E3 Series FA-1 NEW: 7th floor electrical room heat detector is missing (Gamewell FCI 559X rate of rise use with a S911 UL listed base)

Near 6th Ave, Seattle, WA 98101
Jesse S.

Jesse S.

Near SW Dawson St, Seattle, WA 98136
Marlon J.

Marlon J.

Annual Inspections, Extinguishers, Foam samples Hydrants.

Near SW Lander St, Seattle, WA 98134
Zeke  D.

Zeke D.

Confirmed with Bob Frey. Parts and report are on the service shelf in the shop. Troy Davis (residental owner) will be available to let him in.Call 206-683-8769 when you arrive at buildingBackflow Repair Ames 4000B 01320 BFP - 2 Riser Rm Parking: Relief valve would not open. Ames 4000B serial 01320. 1.5" full rebuild kit. Located in FACP riser room at undercover parking.

Near Denny Way, Seattle, WA 98109
Marc P.

Marc P.

Confirmed with Terry/Tony. Any time after 5am. Backflow repair parts are on the service shelf. Assembly passed testing but customer requested check valve replacement due to occasional leaking. Per Tony's Request: **Replacement of #1 check valve assembly on 4" Colt RP-400 backflow prevention device. **

Near 9th Ave, Seattle, WA 98101
Marc P.

Marc P.

Replacement of (2) inoperable horn strobes located on the roof. Confirmed with James

Near E Denny Way, Seattle, WA 98102
Marc P.

Marc P.

Repair parts and report are on the service shelf in the shop. Confirmed with James Rudy the Starbucks Store Manager should be on-site as well Replacement of Relief Valve assembly on 3/4" Watts LF009M3QT. Re-test backflow upon completion of repair.

Near E Denny Way, Seattle, WA 98102
Marc P.

Marc P.

Annual Sprinkler, Fire Alarm, Extinguisher, and Backflow Inspection. Confirmed with Kevin

Near 7th Ave S, Seattle, WA 98108
Jesse S.

Jesse S.

Near University Way NE, Seattle, WA 98105
Jesse S.

Jesse S.

Near 1st Ave W, Seattle, WA 98119
Allec B.

Allec B.

Near 37th Ave S, Seattle, WA 98118
Allec B.

Allec B.

Silent knight 5208 3rd floor electrical room: Annual (1) Fire Alarm Wet SPK-1 Basement Basement/3rd floor: Annual (1) Wet

Near Cherry St, Seattle, WA 98104
Marlon J.

Marlon J.

Repair 4” drain main leak

Near Madison St, Seattle, WA 98104