Now Hiring Call Now Pay Invoice Contact Us

Fire Protection Services Ferndale WA

Request Service

Fire Safety You Can Trust In Ferndale WA

Since 2008, Northwest Fire Systems has been providing the ultimate in fire protection services to the people of Ferndale, WA and the surrounding areas. When it comes to fire safety, they are second to none.

Read below to find out what your neighbors in Ferndale, WA have to say about our service, then call us to ensure your home or business is protected!

Recent Jobs and Reviews in Ferndale, WA

Rated 4.9 out of 5 stars based on 7 customer reviews

Customers say: The reviews exhibit a positive sentiment, with most reviewers expressing satisfaction with the services provided by Northwest Fire. The positive reviews highlight the professionalism, expertise, and excellent customer service of the company's employees, particularly Marlon and Jeff. Customers appreciate the team's ability to resolve issues, provide quality service, and ensure fire safety. The recurring themes include praise for the team's knowledge, friendliness, efficiency, and willingness to go the extra mile. Additionally, customers mention the positive impact of Northwest Fire's services on their job performance and overall satisfaction. However, a few negative reviews exist, primarily focusing on minor issues or delays. These reviews are outweighed by the positive feedback, and the negative comments are not extensive or critical. Overall, the sentiment of the reviews is positive, with customers expressing satisfaction with the services provided by Northwest Fire.

Ferndale, WA at a glance

Northwest Fire Systems has completed 15 jobs in Ferndale, WA between April 2020 and May 2021.

The most recent job was on May 17, 2021.

Northwest Fire Systems completed its first job in Ferndale, WA in April 2020.

Job Locations and Reviews

Brian R.
Brian R. Checked in
Ferndale, WA 98248
Brian R.
Brian R. Checked in
Brian FA service Cody FA service Replaced all batteries except main facp . Need 2x12v18ah nut and bolt type on return trip on 5/17 please allow time for that. Those batteries were not staged Mounted hangin smoke detector No access to directors room add time to fix that on return trip on 5/17 Confirmed all mag doors release power. Doors are getting hung up on carpet. See pictures Trouble shot elevator not recalling. Confirmed it is not the module that is the issue. Called tech support to walkthrough programming and they said the computer software is needed and unable to do group programming through keypad. This is a IFP-1000 proprietary panel we don’t have software for. Need certified dealer to fix programming.
Ferndale, WA 98248
Marc P.
Marc P. Checked in
Annual Fire Alarm, Backflow, Sprinkler, Pre-Action, Fire Pump, Fire Extinguisher, Semi-Annual Kitchen Hood & FM-200 Inspections Deficiency for Silent Knight IFP 1000 FA-1 / 1st Floor Behind Hotel Reception Inside Front Office Door: 4th ,3rd, and 2nd floor north tower elevator lobby fire doors did not close. Hands up on the carpet Deficiency for Ansul R102 KISUP-5 / Panasia (Kitchen): Disregard Deficiency for Silent Knight IFP 1000 FA-1 / 1st Floor Behind Hotel Reception Inside Front Office Door: Batteries are due: Silent Knight VIP Main FACP: Qty 2 12V 18AH Bolt Type Silent Knight VIP Booster Panel under FACP: Qty 2 12V 8AH Silent Knight SK-4 Shed Panel FACP Qty 2 12V 8AH By Room IT5 Qty 4 Silent Knight 5895XL Qty 8 12V 8AH Deficiency for Ansul R102 KISUP-5 / Panasia (Kitchen): PANASIA HOOD- 1) wires in control head need to be installed in a junction box outside of the unit. 2) system failed to trip via fusible link line. 3) salamander oven does not have any nozzle covera
Ferndale, WA 98248
Marlon J.
Marlon J. Checked in
Ferndale, WA 98248
Jesse S.
Jesse S. Checked in
Ferndale, WA 98248
Brian R.
Brian R. Checked in
Replaced AIM, MIM, and laundry room NAC. Panel cleared of all faults.
Ferndale, WA 98248
Brian R.
Brian R. Checked in
Disconnected wires from relay and addressable module for elevator shunt trip. Disabled both modules in programming. Customer said duct detector acr-7 caused sirens to go off earlier this morning. Checked event log and could not find any alarm from that time frame. I inspected the rooftop unit and found the module cover plate not installed and a damp plastic bag sitting on module and wiring. The cover looks like it was not installed due to a tight fit. I shaved the module cover to fit inside ac unit so wiring is not wiring exposed . There is the m19 ground fault still on panel that could cause malfunctions . Waiting on all parts to get ordered.
Ferndale, WA 98248
Brian R.
Brian R. Checked in
Found bad silent knight SD500-MIM relay to shunt in elevator machine room 6th floor North Hotel Also found internal ground fault on M19 silent knight 5895 XL power supply in 1st floor laundry electrical room . Jesse helped trouble shoot over FaceTime . Determined replacing both units.
Ferndale, WA 98248
Brian R.
Brian R. Checked in
Found bad silent knight SD500-MIM relay to shunt in elevator machine room 6th floor North Hotel Also found internal ground fault on M19 silent knight 5895 XL power supply in 1st floor laundry electrical room . Jesse helped trouble shoot over FaceTime . Determined replacing both units.
Ferndale, WA 98248
Jesse S.
Jesse S. Checked in
Ferndale, WA 98248
Marlon J.
Marlon J. Checked in
Ferndale, WA 98248
Marlon J.
Marlon J. Checked in
Ferndale, WA 98248
Marlon J.
Marlon J. Checked in
Ferndale, WA 98248
Jesse S.
Jesse S. Checked in
Ferndale, WA 98248
Jesse S.
Jesse S. Checked in
Ferndale, WA 98248
Request Service
projectpropertyservicecustomeraddressdetailsschedule
Is your project residential or commercial?
Single family home or multi family, such as an apartment building?
Residence
Single Family
Are you in need of a bid for a construction project, or is this regarding emergency service for an existing system?

Heads Up!

You're about to request a bid for a construction project.

If you're in need of emergency service on an existing home, please select "Emergency Service" below.

Who should we contact for information on the project?
*
*
Can you share some information about your project?
(Please answer to the best of your knowledge. We can obtain any missing info later in the process)
*
*
Tell us a few more details about your project:
Is your project New Construction or a Retrofit?
New Construction
Retrofit – New Sprinkler System
Addition to existing sprinkler
*
Is this property serviced by a well?
Yes
No
*
what water district is this property in?
Quality drawings (aka blueprints or plans) allow us to give accurate estimates and give us the framework for designing the sprinkler system.

Please upload your set of building plans by clicking the button below
By pressing Submit I agree to receive phone, email, or text messages from Northwest Fire Systems to the provided mobile number and also agree to the Northwest Fire Systems terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next