Fire Protection Services Kirkland WA

Request Service

Fire Safety You Can Trust In Kirkland WA

Since 2008, Northwest Fire Systems has been providing the ultimate in fire protection services to the people of Kirkland, WA and the surrounding areas. When it comes to fire safety, they are second to none.

Read below to find out what your neighbors in Kirkland, WA have to say about our service, then call us to ensure your home or business is protected!

Recent Jobs and Reviews in Kirkland, WA

Rated 5.0 out of 5 stars based on 19 customer reviews

Customers say: The reviews exhibit a positive sentiment, with most reviewers expressing satisfaction with the services provided by Northwest Fire. The positive reviews highlight the professionalism, expertise, and excellent customer service of the company's employees, particularly Marlon and Jeff. Customers appreciate the team's ability to resolve issues, provide quality service, and ensure fire safety. The recurring themes include praise for the team's knowledge, friendliness, efficiency, and willingness to go the extra mile. Additionally, customers mention the positive impact of Northwest Fire's services on their job performance and overall satisfaction. However, a few negative reviews exist, primarily focusing on minor issues or delays. These reviews are outweighed by the positive feedback, and the negative comments are not extensive or critical. Overall, the sentiment of the reviews is positive, with customers expressing satisfaction with the services provided by Northwest Fire.

Kirkland, WA at a glance

Northwest Fire Systems has completed 25 jobs in Kirkland, WA between October 2020 and July 2021.

The most recent job was on July 20, 2021.

Northwest Fire Systems has completed 1 job in Kirkland, WA in the last 12 months. The first job there was in July 2018.

Job Locations and Reviews

Brian R.
Brian R. Checked in
Kirkland, WA 98034
Thomas M.
Thomas M. Checked in
Deficiency Repairs Installed head box Head wrench 6 spare heads
Kirkland, WA 98033
Ryan H.
Ryan H. Checked in
Annual Sprinkler, Fire Alarm and Fire Extinguisher Inspections
Kirkland, WA 98033
Ryan H.
Ryan H. Checked in
5-year Smoke Detector Sensitivity Testing (7) Smoke Detectors - Replacement of (3) 12V 8Ah Batteries
Kirkland, WA 98033
Ryan H.
Ryan H. Checked in
5-year Smoke Detector Sensitivity Testing (7) Smoke Detectors - Replacement of (3) 12V 8Ah Batteries
Kirkland, WA 98033
Allec B.
Allec B. Checked in
Kirkland, WA 98034
Caleb K.
Caleb K. Checked in
Kirkland, WA 98034
Caleb K.
Caleb K. Checked in
Kirkland, WA 98034
Allec B.
Allec B. Checked in
Kirkland, WA 98033
Marc P.
Marc P. Checked in
Deficiency Repairs Dry SPK-1 / West Side of Bldg by Elevator 4” CSC AG: Missing (1) spare sprinkler head inside spare head box. Ames 2000B 0003842 BFP-2 / W Side of Bldg Inside in Sprinkler Room: Backflow failed testing. #1 & #2 check valve assemblies leaked - Recommend rebuild of #1 & #2 check valve assemblies. 3/4" Ames 2000B Serial #0003842 Located in fire sprinkler riser room on West side of building. Ames 3000SS 3LM0782 BFP-1 / W Side of Bldg Inside in Sprinkler Room: Backflow failed testing #1 & #2 check valve assemblies leaked - Recommend rebuild of #1 & #2 check valve assemblies. 4" Ames 3000SS Serial #3LM0782 Located in fire sprinkler riser room on West side of building. Febco 850 A00677 BFP-3 / in-front BLDG 811. Near sidewalk, L side drvwy if looking at the road.: Backflow preventer assembly does not have 6 inches clearance under assembly. Assembly passed, but was dug up to test - It is covered in tree roots and buried in dirt. Customer will need to make sure there is 6" of
Kirkland, WA 98033
Marc P.
Marc P. Checked in
Deficiency Repairs Deficiency for Dry SPK-1 / West Side of Bldg by Elevator 4” CSC AG: Missing Sprinkler Head inside spare head box Deficiency for Ames 3000SS 3LM0782 BFP-1 / W Side of Bldg Inside in Sprinkler Room: Check Valve 1 & 2 plummets straight to 0 when testing Deficiency for Ames 2000B 0003842 BFP-2 / W Side of Bldg Inside in Sprinkler Room: Check Valve 1 & 2 Plummets to zero Suggested for Febco 850 A00677 BFP-3 / in-front BLDG 811. Near sidewalk, L side drvwy if looking at the road.: Backflow preventer assembly does not have 6 inches clearance under assembly. Assembly passed, but was dug up to test. it is covered in tree roots and buried in dirt.
Kirkland, WA 98033
Zeke D.
Zeke D. Checked in
Annual Fire Sprinkler,
Kirkland, WA 98034
Andy D.
Andy D. Checked in
Kirkland, WA 98034
Colby F.
Colby F. Checked in
Kirkland, WA 98034
Andy D.
Andy D. Checked in
Kirkland, WA 98034
Marc P.
Marc P. Checked in
) FDC check valve located at riser. Febco 805Y 149981 BFP-3 / 15' NW of Main Water Meter in Irrigation Box: Backflow failed testing. #1 check valve assembly failed - Recommend full rebuild kit for #1 & 32 check valve assemblies. Backflow is under water due to rain. 3/4" Febco 805Y Serial #149981 Located 15' NW of main water meter in irrigation box. Recommend scheduling this in warmer/dryer weather - won’t be able to repair when it’s under water. Dry SPK-1 Sprinkler room in Garage: Dry sprinkler system due for 3 year full trip. To be scheduled in Spring.
Kirkland, WA 98033
Marc P.
Marc P. Checked in
Annual Sprinkler Inspection
Kirkland, WA 98034
Colby F.
Colby F. Checked in
Kirkland, WA 98034
Colby F.
Colby F. Checked in
Kirkland, WA 98033
Jordan H.
Jordan H. Checked in
Kirkland, WA 98034
Cody K.
Cody K. Checked in
Kirkland, WA 98034
Brian R.
Brian R. Checked in
Monitoring conversion
Kirkland, WA 98034
Jeff M.
Jeff M. Checked in
Kirkland, WA 98034
Larry M.
Larry M. Checked in
Fire Alarm Service Call
Kirkland, WA 98033
Marc P.
Marc P. Checked in
Kirkland, WA 98034
Request Service
projectpropertyservicecustomeraddressdetailsschedule
Is your project residential or commercial?
Single family home or multi family, such as an apartment building?
Residence
Single Family
Are you in need of a bid for a construction project, or is this regarding emergency service for an existing system?

Heads Up!

You're about to request a bid for a construction project.

If you're in need of emergency service on an existing home, please select "Emergency Service" below.

Who should we contact for information on the project?
*
*
Can you share some information about your project?
(Please answer to the best of your knowledge. We can obtain any missing info later in the process)
*
*
Tell us a few more details about your project:
Is your project New Construction or a Retrofit?
New Construction
Retrofit – New Sprinkler System
Addition to existing sprinkler
*
Is this property serviced by a well?
Yes
No
*
what water district is this property in?
Quality drawings (aka blueprints or plans) allow us to give accurate estimates and give us the framework for designing the sprinkler system.

Please upload your set of building plans by clicking the button below
By pressing Submit I agree to receive phone, email, or text messages from Northwest Fire Systems to the provided mobile number and also agree to the Northwest Fire Systems terms and privacy policy. Message & data rates may apply. Consent is not a condition of purchase. We will never share your personal information with third parties for marketing purposes.
Back Next